NiGen LCMS 40-1 and 100 - background
Products

NiGen LCMS 40-1 and 100

Designed for LCMS e Sample preparation

GAS TYPE
nitrogen

PURITY
up to 99.9%

CONFIGURATION
-

Request information
NiGen LCMS 40-1 and 100 - image
Features
Models
Technical specifications
Applications
Download
  • Available in 2 models:
    - the NiGen LCMS 40-1 model from
    40 Nl/min with compressor
    - the NiGen LCMS 100 model from
    100 Nl/min without compressor
  • Capable of supplying up to 4 LC-MS
    analyzers
  • The NiGen LCMS 40-1 equipped
    with an integrated Full Oil Free
    compressor
  • Equipped with special soundproof
    and anti-vibration devices
  • 2 internal air and nitrogen
    tanks, 50 liters each, that allow
    fewer internal air compressor
    interventions, reducing both noise
    and maintenance
  • Compressor maintenance required
    after only 16,000 hours of work
  • Touch screen display that allows
    monitoring of the operating
    status and menu reading with the
    maintenance status, the alarm
    report and functional parameters
  • NiGen LCMS 40-1
  • NiGen LCMS 100
FLOW RATE NiGen LCMS 40-1 : 38 Nl/min ± 10% a 2000 m asl
NiGen LCMS 100 : 100 Nl/min ± 10% a 2000 m asl
TECHNOLOGIES EMPLOY PSA CLAIND
OUTPUT PRESSURE 0 - 7 bar/0 - 100 psi ± 3%
PURITY up to 99.9%
COMPRESSOR Only in the version 40-1
AIR INPUT CHARACTERISTICS Particulate ≤ 0,01 µm
Oil vapors ≤ 0,01 mg/m3
Moisture ≤ 3° C dew point
min pressure: 8.5 bar/120 psi
max pressure: 10 bar/145 psi
ELECTRICAL SUPPLY x LCMS 100 115/230 Vac ± 10% 60/50 Hz 50 W
ELECTRICAL SUPPLY x LCMS 40-1

115 Vac ± 10% 60 Hz 1,9 kW
230 Vac ± 10% 50 Hz 1,6 kW

INDEX OF PROTECTION IP20
NOISE < 50 dBA during the stand by of the compressor
< 65 dBA with compressor running
OPERATING TEMPERATURE 5°C fino 35°C (41°F fino 95°F)
ENVIRONMENTAL HUMIDITY max 90% without condensation
DIMENSIONS Height: 132 cm/52”
Width: 44 cm/17.3”
Depth: 110 cm/43.3”
WEIGHT version 40-1:220 kg/489 lbs
version 100: 200 kg/444 lbs
PNEUMATIC CONNECTIONS Compressed air inlet: G 1/4” female
Nitrogen output: G 1/4” female
  • LCMS
  • Sample preparation
  • Glove Box
User Manual NIGEN LCMS
User Manual NIGEN LCMS Download
Product Sheet NIGEN LCMS
Product Sheet NIGEN LCMS Download

NiGen LCMS 40-1 and 100

Designed for LCMS e Sample preparation

NiGen LCMS 40-1 and 100

Discover all after-sales services

At Claind we are committed to a high standard of service and to promptly responding to all of our customers' requests.

Discover all after-sales services
Documentation download

Richiesta avvenuta correttamente!

Ti ringraziamo per il tuo interesse.
Riceverà presto una mail con i link per i file richiesto!

Fill the form to receive the download link for the required material
Enter a valid e-mail addressAn error has occurred. Please try again later.

Fields marked with an asterisk (*) are mandatory

Newsletter

Subscribe to our Newsletter.

Subscribe